Domain 5 · Sterile Storage, Transport and Inventory Management
A wrapped tray is found with a damp corner after cooling. What should happen next?
Incorrect — moisture can create a pathway for microorganisms. Drying does not restore the sterile barrier.
Correct — visible moisture is a compromising event, so the item cannot be considered sterile.
Incorrect — intended use does not repair a compromised package.
Incorrect — a dust cover protects an intact package; it cannot restore sterility.